ELECTRONIC MULTIMETER QLC-110/110L
(stopped,replace model:SQLC-110L or SFLC-110L)
※ Cost reduction of distribution panel Compatible with various needs w/ back light
■FEATURES
Various kinds of electrical elements, in each phase of three-phase line, both of low voltage and high voltage circuit, such elements as voltage, current, power, reactive power, power factor, frequency can be measured and monitored in one single unit.
Energy saving management is also possible by watthour measuring function.
※Circuit indication of R-Y-B and U-V-W are available.
■ MAIN SPECIFICATIONS
●Single-phase 2-wires or 3-wires, three-phase 3-wires or 4-wires(110V/220V. 1A/5A)
● Output(Option: Analog, Pulse or Communication)
● Auxiliary power source: AC/DC common(AC85‐253V/DC80 ‐143V) or DC(20‐56V)
● Withstand voltage: 2000V ●with a Terminal cover
ELECTRONIC DC RECEIVING METER XLC-110/110L
※Simultaneous display of 3 physical quantities with easy-to see LCD screen Easy scaling change
■FEATURES
Display of electrical signal which is converted from various physical quantities
Centralized management is possible with simultaneous display of 3 physical quantities and 3 proportional Analog outputs
■ MAIN SPECIFICATIONS
● Compatible with 3 inputs and 3 outputs ● Input: DC4‐20mA, DC 1‐5V, other
● Output (Option): DC4‐20 mA, DC1‐5V/other
● Auxiliary power source: AC/DC common(AC85‐253V/DC80 ‐143V) or DC(20‐56V)
● Withstand voltage: 2000V ● with a Terminal cover
ELECTRONIC VOLTAGE MULTIMETER VLC-110/110L
(stopped,replace model:SVLC-110L)
※Most suitable for distribution panel standardization with easy-to-see LCD screen
■FEATURES
3-phase voltage can be measured and monitored in one single unit.
Most suitable for voltage measuring of power receiving, bus bar and feeder.
Line to line can be displayed by Phase Changeover Switch.
■ MAIN SPECIFICATIONS
● Single-phase 3-wires, three-phase 3-wires(110V/220V)
● Output (Option: Analog)
● Auxiliary power source: AC/DC common(AC85‐253V/DC80 ‐143V) or DC(20‐56V)
● Withstand voltage: 2000V ●with a Terminal cover
ELECTRONIC OVERLOAD/LEAK DETECTION METER RELAY
LLC-110/110L
(stopped,replace model:SQLC-110L)
※Most suitable for leakage current measuring/leak detection with easy-to-see LCD screen
■FEATURES
Various kinds of electrical elements, in each phase of three phase line, such elements as current, voltage and leakage current can be measured and monitored in one single unit.
Most suitable for monitoring of overload/leakage current of low voltage circuit.
Overload alarm output, leak alarm output can be extracted outside.
■ MAIN SPECIFICATIONS
●Single-phase 3-wires, three-phase 3-wires(110V/220V. 1A/5A ZCT)
● Output(Option: Analog)
● Alarm output
● Auxiliary power source: AC/DC common(AC85‐253V/DC80 ‐143V) or DC(20‐56V)
● Withstand voltage: 2000V ●with a Terminal cover
ELECTRONIC DC MULTIMETER TLC-110/110L
※Most suitable for measuring of DC power board and DC circuit such as wind power generation, solar power generation, fuel battery, etc
■ FEATURES
Voltage or current of DC circuit(3 circuits at maximum) can be measured.
Insulated among input circuits with AC2000V. As for current of DC circuit, heavy current can be measured by using shunt.
Centralized control is possible with Analog output.
■ MAIN SPECIFICATIONS
●Voltage: DC±50 ‐ ±300V, DC current(compatible with shunt) 50mV,60mV,100mV
●Shunt rated current: 1A to 10kA ● Display setting with requested voltage/current value
● Output(Option): DC4‐20mA, DC1‐5V, other ● Auxiliary power source: AC/DC
common(AC85‐253V/DC80 ‐143V)
● Withstand voltage: 2000V ● w/ Terminal cover
ELECTRONIC CURRENT MULTIMETER ALC-110/110L
(stopped,replace model:SALC-110L)
※Most suitable for distribution panel standardization with easy-to-see LCD screen
■FEATURES
3-phase current can be measured and monitored in one single unit.
Most suitable for current measuring of power receiving, bus bar and feeder.
Phase to phase can be displayed by Phase Changeover Switch.
■ MAIN SPECIFICATIONS
● Single-phase 3-wires, three-phase 3-wire(1A/5A)
● Output (Option: Analog)
● Auxiliary power source: AC/DC common(AC85‐253V/DC80 ‐143V) or DC(20‐56V)
● Withstand voltage: 2000V ● w/ Terminal cover
ELECTRONIC DEMAND MULTIMETER DLC-110/110L
(stopped,replace model:SQLC-110L or SFLC-110L)
※Most suitable for demand current measuring of low to high voltage circuit feeders Complied to criterion specified by Japanese Government(Ministry of Land-Infrastructure-Transport)
■ FEATURES
Various kinds of electrical elements, in each phase of three phase line, such elements as maximum demand current, demand current, instantaneous current, voltage, power factor powers(maximum, demand, instantaneous) and watthour can be measured and monitored in one single unit.
Energy saving management is possible by watthour measuring function and centralized management is also possible with combination of Alarm/Analog output or Alarm/Communication output.
※Circuit indication of R-Y-B is available.
■ MAIN SPECIFICATIONS
●Single-phase 2-wires or 3-wires, three-phase 3-wires or 4-wires(110V/220V. 1A/5A)
● Output(Option: Analog, Pulse or Communication)
● Alarm output(Option)
● Auxiliary power source: AC/DC common(AC85‐253V/DC80 ‐143V) or DC(20‐56V)
● Withstand voltage: 2000V ● w/ Terminal cover
ELECTRONIC MULTIMETER SQLC-110/110L |